Gloss White Wall Panel 5mm (4 Pack)

£36.51 Ex Tax: £30.43
Gloss White Wall Panel 5mm (4 Pack)

Width / Length (mm) 250 x 2600


Where Roof Liner can be fitted

To the walls and ceiling of any room in the house, office, factory or food preparation area. Includes shower cubicles with power shower up to maximum 60ºC.

To damp or damaged walls by fitting 38mm x 19mm battens horizontally at 600mm centres with screws into wall plugs and, if required, a breather membrane. 

To a wall or ceiling with a clean flat surface using adhesive (no battening required).

To a wall or ceiling with ceramic tiles, using a moisture cure or solvent free adhesive (tiles do not have to be removed). 

Roof Liner can withstand temperatures up to 60ºC. It can be fitted behind hot water pipes and radiators and behind a gas or electric hob if a piece of heat resistant glass is installed between the product and the hob using 10mm spacers and mirror screws.

Steam Rooms – Not for use in Steam Rooms where hot spot temperatures may exceed 60ºC. Direct contact with the steam from kettles or pans must be avoided.

Installation Process

Boards fitted to flat, dry walls and ceilings

Select and fit trims required (see section below). All trims should be secured with 4mm countersunk screws.

Select the first board and remove the tongue on the left of the board and cut to length. Remember, if the last board in the run is on a feature corner, you could remove more of the first board in order to finish witha complete board.

Painted surfaces should be suitably keyed before applying any adhesive.

Starting from the left, fit the board into the trim using a spirit level to ensure the board is vertical.

Make sure the board is securely bonded to the wall.

Mitre the front face of ceiling trims where necessary.

When fixing to tiled walls a moisture cure silicone or solvent free adhesive should be applied.

Boards fitted to Damp or Damaged Walls

Secure a breather membrane to the walls.

Fit wooden battens (38mm x 19mm) to the wall; horizontally at 400mm centres and vertically at all intersections, corners and abutments in order to support finished ends.

Secure the trims to the battens with 4mm countersunk screws or 12mm staples at 400mm centres.

Select the first board and remove the tongue on the left of the board and cut to length. Remember, if the last board in the run is on a feature corner, you could remove more of the first board in order to finish with a complete board.

Secure each board with countersunk screws or 12mm staples.

Mitre the front face of ceiling trims where necessary.

Installation Notes

On corners, either use a corner trim or slit back face of board and bend around angle. Firmly secure bent board and previous board using screws.

Do not mount load bearing accessories, eg. grab handles, directly on to Marbrex panels. When mounting accessories on the wall, take up the depth of the board with wood or other suitable spacers & seal with silicone.

In a shower area apply a narrow silicone bead to the face of theright-hand flange to ensure complete protection against moisture.

Run a silicone bead around the edge of a bath or shower tray. Fit ends of boards down onto bead to seal.

Cleaning

Apply a non-abrasive household cleaner (can contain bleach in solution) with a soft cloth or sponge. Do not use neat bleach. Rinse with water.

Performance

Room liner achieves a Class 1 fire rating and conforms to the requirements of the Food Safety Act 1990 and General Hygiene Regulations 1995

Write a review